7 tips for arranging a boiler room in a private home: requirements and standards

In order not to freeze in your home in winter, you will have to heat it using various types of fuel. Since conventional stoves are considered a relic of the past, houses are heated using gas or another type of fuel, but using a more advanced heating scheme. Installation of such heating equipment requires a separate room. Such a room is called a furnace room, boiler room, but most often a boiler room. There are certain requirements for this kind of premises, since any type of fuel is considered dangerous. Therefore, it is necessary to ensure the safest possible operation of the boiler room.

Regulations

To install boiler equipment in a private home, you must rely on a number of rules. Until mid-2003, some standards were in force, and from mid-2003 other standards began to apply (SNiP 42-01-2002), so this document should be followed.


A boiler room in a private house must meet a lot of requirements

It is advisable to familiarize yourself with these standards, although specialized organizations are involved in design documentation. After reading the documents, you can decide in advance what equipment can be installed and what cannot be installed in a private home. In this case, you can also decide what preparatory work will have to be done so that the equipment can be installed without delaying the entire process. If any difficulties arise, you must contact the design department for help, since they know exactly all the intricacies of installing this type of equipment, depending on the specific plan of the residential building.

Scheme with hydraulic arrow

The water arrow in the boiler room circuits of the house prevents the occurrence of thermal shock. The essence of its action is to separate and link several circuits.

Carrying out one-time operation of heating, hot water supply, heated floors involves an unstable load and variability of the thermo-hydraulic properties (temperature, pressure drops) of the networks. The heat supply source does not tolerate instability well, so a hydraulic arrow is installed between it and the consumer branches.

The main function of the device is to set the coolant in the desired direction automatically in order to avoid thermal shock.

Installing a gas boiler in a private house: installation rules


Option for installing a wall-mounted gas boiler - at least 10 cm to the wall.
To choose a place to install a gas boiler, you need to take into account the power of the boiler.

So:

  • If the boiler power is no more than 60 kW, then it is permissible to install it in the kitchen, but subject to certain rules.
  • If its power exceeds 60 kW, but does not exceed 150 kW, then the boiler must be placed in a separate room, regardless of what floor it is on.
  • When the boiler power ranges from 150 kW to 350 kW, it is installed in a separate room located on the first or ground floor, in an extension or in a separate building.

Naturally, this does not mean at all that boilers with a power of less than 60 kW are not allowed to be located in a separate room. Sometimes it is even necessary, since all life support elements are located in one place that is quite convenient for maintenance. Despite this, you will have to take into account the size of this room. The dimensions of the room, depending on the power of the boilers, must meet the following parameters:

  • Boilers with a power of up to 30 kW are installed in rooms with a volume of at least 7.5 cubic meters.
  • For boilers with a power from 30 to 60 kW, the volume of the room should not be less than 13.5 cubic meters.
  • Boilers with a power of 60 to 200 kW must operate in rooms with a volume of at least 15 cubic meters.

It should be noted that this does not mean the area of ​​the room, but its volume. If the boiler is planned to be installed in the kitchen, then there are completely different requirements - the volume of the kitchen is at least 15 cubic meters, and the ceilings should be located at a height of 2 and a half meters.

There are also general requirements for the premises in which heating equipment is planned to be located.

So:

  • Regardless of the nature of the boiler room, it must have electric lighting. The area of ​​the windows should be 1 m. cubic not less than 0.03 m. square glazing. Again, not the area of ​​windows with frames, but purely the area of ​​glass. In this case, the windows must open outward.
  • The window should have a window or transom.
  • Ventilation is provided, as well as disposal of combustion products through the installation of a chimney. Low-power boilers (up to 30 kW) can be equipped with a chimney that passes through the wall.
  • It is also necessary to provide for the availability of water and sewerage.

Recent regulatory documents are characterized by the presence of one more general rule. If the boiler power is over 60 kW and there is a hot water circuit, it will be necessary to install a gas level sensor that turns off the gas supply automatically if the level of harmful gases in the room is exceeded.


If there is a boiler and a heating boiler, when determining the size of the boiler room, their power is summed up

Requirements may differ significantly depending on the type of boiler room and the equipment installed in it.

✅ Boiler room in a private house of 180 sq.m. And a warm water floor. // Sasha Bagot

Tools and materials for building an extension

The construction of an extension to a house for equipping a boiler room requires the use of tools for engineering, general construction and facing work; they are not scarce and technically complex and, as a rule, are present in every household:

  • shovels and crowbar for excavation work;
  • concrete mixer, containers for transferring mortar for pouring the foundation;
  • carpentry tools for performing formwork work;
  • mason's set: rulers, angles, plumb lines, trowel, trowel and spatula for masonry work;
  • grinder, drill, hammer, pliers for installing a reinforced belt and fastening the formwork for the foundation;
  • chainsaw for roofing.

Wall material is purchased according to design specifications by type and quantity with a margin of 10-15%. If these are foam blocks, then you will also need a dry adhesive mixture.

It is better to purchase material from a stone manufacturer with quality certificates, and not from an unknown seller. Also, you should not take very cheap blocks, which may indicate poor quality of wall products. For work, well-dried material is used, the masonry process is carried out in a warm and dry period of time.

Boiler room in a private house in a separate room

A separate room is required when the boiler power is more than 60 kW, but does not exceed 200 kW, and this room must be equipped with a fire-resistant partition with a fire resistance level of about 45 minutes. Brick, cinder block and lightweight concrete fall under similar characteristics, not to mention heavy concrete.


It is not the area of ​​the boiler room that is standardized, but its volume; the minimum ceiling height is also set

It should be recalled what requirements apply to such premises:

  • The volume of the room is at least 15 cubic meters.
  • The ceiling height is at least 2.5 meters with a power of up to 30 kW and from 2.2 meters with a lower boiler power.
  • The presence of a window with a transom, as well as a glazing area of ​​at least 0.03 square meters per cubic meter. volume meter.
  • Ventilation should exchange air three times within an hour.

If the boiler room is located on the ground floor or in the basement, the requirements are more stringent, and for every one kilowatt of power you will have to add 0.2 cubic meters, taking into account the mandatory 15 cubic meters. The walls must also be made of materials that do not allow gas and steam to pass through. If you plan to install equipment with a power of 150 to 350 kW, you will have to provide the boiler room with a separate exit to the street. It is acceptable for the exit to be connected to a corridor that leads to the street.

As a rule, premises for arranging a boiler room in a residential building are selected with a focus on ease of maintenance, so they significantly exceed all requirements.

Attached boiler rooms: requirements

The previous requirements, plus some new ones, apply to such premises.


The extension is made of non-combustible building material

So:

  1. A room is built on a solid section of the wall so that the distance to the nearest windows and doors is at least 1 meter.
  2. For construction, non-combustible material is used, in the form of brick, cinder block or concrete.
  3. The walls of the extension are not connected to the walls of the residential building. In other words, the extension will have to be provided with a separate foundation, as well as four walls.

What nuance still needs to be paid attention to? If the boiler room is attached to an already built house, but there is no suitable room and the ceiling height does not allow the installation of boiler equipment, then the organization will help solve this problem by requiring an increase in the glazing area. If the house is just being built, then you will have to meet all the standards, otherwise the project will not be approved in any case. The requirements for attached boiler rooms are extremely stringent, so you will have to maintain all the characteristics.

Summing up

The legislative framework changes frequently, so already at the preliminary stage of designing a combustion chamber it is important to study all current standards and regulations. When planning to install a powerful furnace, it is wise to contact specialized organizations.

Believe me, saving on the work of professionals often leads to a significant overpayment during operation, as well as extremely unpleasant and dangerous consequences for the life and health of your household. Even if the boiler room is small, be sure to consult with specialists.

Installing a gas boiler in the kitchen: room requirements

In the kitchen it is permissible to place gas boilers with a power of up to 30 kW and which are equipped with a combustion chamber of any design, with the boiler located both on the floor and on the wall.


The requirements for installing a gas boiler in the kitchen mostly relate to volume and ventilation

The following requirements apply to the premises:

  • Ceiling height is within 2.5 meters.
  • The volume of the room is not less than 15 cubic meters.
  • Effective ventilation system.
  • Availability of fresh ventilation.

When hanging boilers on walls, the latter must be constructed of fire-resistant materials. The distance to the side walls should be at least 0.1 meters. In the absence of such walls, installation of boilers is allowed, provided that there is a non-flammable gap of 5 cm between the flammable walls and the boiler itself. This could be a layer of plaster or a non-flammable screen made of fire-resistant material.

The screen can be made of sheet steel; the dimensions of the sheet should be 0.7 meters larger in height and 0.1 meters larger on all other sides, compared to the dimensions of the boiler itself. Between the sheet steel and the combustible base, a layer of fire-resistant material, about 3 cm thick, is laid. This may be asbestos or other fire-resistant material.

Chimneys

Chimneys are divided according to the type of installation: - External attached - Double, horizontal, that is, coaxial turbocharged - Internal vertical - Horizontal chimney Horizontal chimneys are very easy to implement, you just need to make a hole in the side wall of the boiler room. Such chimneys are made only with forced ventilation of exhaust gases. Since side winds can disrupt the natural release of gases. The height from the exit pipe from the building to the street floor (ground) should not be less than 2 meters. It is especially problematic to do this in basements, where when exiting through the side wall we do not have enough height from the street floor. The low altitude is fraught with the possibility of snow accumulations in winter, which may prevent exhaust gases from escaping.


It is also not safe; passing gases can pass through people passing by or nearby and poison their breath. Typically, coaxial or turbocharged wall-mounted gas boilers are equipped with a horizontal chimney. In such boilers, the chimney has two pipes (a pipe in a pipe) and there is an additional flow of air for combustion of gases

Vertical chimneys

Vertical chimneys in which the end of the chimney pipe reaches the roof or higher, ventilation occurs naturally, since the warm exhaust gas is lighter than atmospheric air, and as a result of this, there is a force pushing the exhaust gas to the top. Such chimneys must be thermally insulated to reduce the formation of abundant condensation on the pipe walls. The resulting liquid leads to premature aging of the pipe due to corrosion. Even if you have thermally insulated the pipe, condensation will still accumulate, but much less. A hole must be made at the bottom of each pipe to remove condensate. It is also necessary to provide for cleaning the chimney.


The pipe must be strictly vertical so that gas services can check the pipe for clearance. There may be a pocket at the bottom of the pipe to catch falling sediment. Over time, deposits build up on the pipe walls and these deposits can fall down. And to prevent these deposits from clogging the pipe, it is necessary to make a small pocket at the bottom for the accumulation of debris. To avoid fires, the chimney pipe should not be touched by flammable materials, at least at a distance of at least 200mm.


The internal diameter of a chimney with a natural smoke outlet must be at least 130mm. According to the websites: elport.ru, interiorgid.ru, better-house.ru, pro-teplo.info

Free-standing combustion chambers: requirements


A separate boiler room can be like this.
A separate room for arranging a boiler room will be required if the boiler power is more than 200 kW. Such buildings must have the following parameters:

  • The construction is made entirely of non-combustible materials.
  • The volume of the room is at least 15 cubic meters with the addition of 0.2 cubic meters per kilowatt of power.
  • The ceiling location is not lower than 2.5 meters from the floor level.
  • The glazing area is not less than 0.03 square meters per cubic meter of volume.
  • The window is equipped with a window or transom.
  • The boiler is mounted on a separate foundation, the height of which is no more than 15 cm compared to the height of the floor.
  • If the boiler weighs no more than 200 kilograms, then it can be installed directly on the floor if it is concrete.
  • The heating system must include an emergency gas shut-off sensor.
  • Doors should not be reinforced; they should be loosely secured.
  • Availability of an effective ventilation system.

Permission to put heating equipment into operation will be issued only if all requirements are met.

Equipment options

The type of fuel and device affects the conditions of the premises being used. When choosing an equipment option, you first need to provide for all the nuances and arrange the room in accordance with all established requirements for safe operation.

Modular

This option is very rare and is used if it is not possible to use other options. Available ready to run.


Small solid fuel modular boiler room Source termico.com.ua

See also: Catalog of companies that specialize in autonomous gasification of country houses

Represents the following device:

  • container up to 2.5 m long;
  • of varying power, but are mainly used for buildings with an area of ​​no more than 1300 m³;
  • The walls of the device are double, with insulation;
  • diesel and solid fuel are used;
  • It is connected to the house through a pipe, it must have insulation.

It is advisable to place it nearby and can be transported. Before use, it is connected to the power supply and the system is filled with water. Often these models have backup power.

Choosing doors to the boiler room

If the boiler room is located inside a residential building, then the doors to this room must be made of fire-resistant material that can withstand fire for 15 minutes. As a rule, these conditions correspond to doors made of metal, and they can be either factory-made or home-made.

If the furnace room is equipped with doors facing the street, then they should be loosely secured. This will allow, in the event of a gas explosion, to protect the boiler room from destruction by the blast wave, which will soften its blow after the doors with the frame are pushed out onto the street. The advantage of such doors is that gas can freely exit the boiler room.

In projects you can find an additional condition, which refers to the presence of a grille at the bottom of the door that covers the through hole. This hole will allow fresh air to flow freely into the boiler room.

Ventilation arrangement in the boiler room

Ventilation in the boiler room should be so effective that it can provide three times the air exchange in one hour. To determine the performance of ventilation equipment for a specific room, you need to take the volume of this room and multiply by three, and then add a 30 percent margin.

For example, if you take a boiler room with dimensions of 3.5x3.5x2.5 meters, you will get a volume equal to 30.625 cubic meters. If this result is multiplied by 3, the volume will be 91.875 cubic meters. If we add a 30 percent reserve to this result, we get a volume equal to 119.4375 cubic meters. In other words, ventilation should renew about 120 cubic meters of air in the room every hour.

For ventilation to really work effectively, it is necessary to install supply ventilation with a grille in the wall, closer to the floor. The exhaust pipe can also be run through the roof or through the wall closer to the ceiling. The outlet of the ventilation pipe must be located at the same level as the outlet of the chimney.

Installation of solid and liquid fuel boilers: requirements


Liquid fuel boilers usually operate noisily.
Basically, the rules for arranging premises are the same regardless of what type of fuel they operate on. Despite this fact, there are a number of separate requirements in terms of arranging a chimney, as well as arranging a place for storing fuel. As a rule, the requirements are mentioned in the passport, and they boil down to the following:

  • The working thickness of the chimney should not be less than the dimensions of the outlet pipe, and over its entire length.
  • The chimney design should have the smallest number of bends, and it should be straight.
  • At the bottom of the wall it is necessary to equip a hole for fresh air ventilation, at the rate of 8 cm square per kilowatt of power.
  • Combustion products can be discharged either through the roof or through the wall.
  • Below the chimney level, a special cleaning hole should be located to facilitate the inspection and maintenance process.
  • The chimney is mounted from non-flammable and gas-tight material.
  • The boiler should be installed on a non-combustible base, especially if the floors in the room are wooden. First, asbestos is laid on the floor, then sheet metal, and only then the boiler.
  • If the boiler is coal-fired, then additional requirements are imposed on it, since coal dust is considered explosive.

You should also pay attention to the fact that the chimney can be exhausted both through the roof and through the wall using a non-combustible passage unit.

Here we should mention boilers running on liquid fuel. Their functioning is associated with a number of disadvantages that must be taken into account. Firstly, they make a lot of noise, and secondly, they give off a specific smell of flammable material. Naturally, such a boiler can hardly be installed in the kitchen, and in residential premises (as well as in non-residential ones, but within the house), it simply does not make any sense. For such boilers it is necessary to provide separate rooms. That is why such boilers are practically not used for heating residential buildings (private buildings).

What to consider before starting work

The extension must be officially registered. Without the appropriate document, gas services do not have the right to authorize gas supply to it, so you will need to order a project from a specialized design organization and coordinate it with the regulatory authorities: architecture, SES, Ministry of Emergency Situations and the gas supply company.

Before starting design, the owner of the house will have to take technical specifications from gas workers, power engineers and water supply organizations, which must be taken into account in the extension projects.

Before starting construction, the following mandatory measures are carried out:

  • selection of a site for the construction of a furnace;
  • preliminary calculation of the size of the extension with the choice of material;
  • calculation of communications for compliance with the increased power in connection with the commissioning of the boiler house;
  • making a decision on the arrangement of the passage between the building and the furnace, door and window structures.

After completing the construction of the extension for the furnace room, it will be necessary to make changes to the technical passport of the house in the architectural authorities and BTI.