Residents of the Moscow region were told how heating fees are calculated


Changes in 2019 that affected heating

When calculating heating payments in apartment buildings, some parameters have changed:

  1. There were two heating options, it was divided into 2 categories: individual and communal.
  2. We have developed special formulas for calculating those square meters and rooms that are not heated, and for residential areas with autonomous heating.
  3. Individual calculation of heating payments has appeared in multi-apartment buildings, which are only partially equipped with heat meters.

Also, for a more detailed calculation, new indicators were introduced that affect the amount of payment. Such as the area of ​​common areas and the amount of Gcal of heat consumed. This value is the sum of the indicators that were taken from individual heat metering equipment or installed on the heating systems of the owners of radiator distributors.

How to calculate the amount yourself

You can calculate the amount of payment for heating in your apartment yourself. But before that, consider some factors:

  1. Determine how many months a year the payment for heat occurs. Only for the period when hot water is supplied to the batteries or throughout the calendar year.
  2. Find out if your apartment building has a communal heat meter installed.
  3. Find out whether your living space is equipped with a separate heat meter or its own radiator distributors.
  4. Determine how the heating system in your living space is filled with hot water. Via the central city system or through special equipment installed in your home.

Based on these parameters, you can use certain formulas to calculate payments for heating an apartment.

What are the rules for calculating payments for heat?

Be guided by the parameters that you have defined for your home and use the ready-made formula to calculate by category:

  1. When there is no common house heat meter (DHMU), and payments for heat supply are charged only during the months of the heating season.
  2. If there is no general income tax, and payments are extended over the entire calendar year.
  3. The house is connected to an ODPU, but separate meters are not installed in any of the premises of the building.
  4. The building has an ODPU installed, the apartments are partially equipped with separate devices for calculating heat energy.

If your apartment is located in a building in which ODPU are not connected, and the payment is assigned only during the heating period, the heat energy is calculated according to the standards. This is a fixed amount of energy that is required to heat 1 square meter. meters for 30 days. Standards vary depending on the region; they are adopted and approved by local leadership, taking into account climatic conditions. In this case, you can use the following formula:

P = Plz x Np x Tt

Plzh - housing area. NP - consumption standard. Тт —heat tariff.

For buildings without DPPU, in which payments are spread over 12 months, the calculation includes the coefficient of frequency of payment for utilities for heat energy. The coefficient is equal to the number of payments for the heating season divided by 12 months. And the calculation will be made according to the following formula:

P = Pl x Np x Kf x Tt

Where Kf is the calculated coefficient for monthly accounting.

Additional calculation formulas

Meters for calculating heat energy in an apartment building are installed upstream of the building. The device shows how much heat is supplied to the apartments of the entire building. Heat is calculated proportionally for all apartments. The calculation is carried out as follows:

P = (Rebt + (Plzh x (Ot - ∑Rebt)) / Plob) x Tt

Plzh is the area of ​​the apartment. Floor area - the total area of ​​residential and non-residential premises in a building. From - the volume of heat energy according to the ODPU readings when paid during the heating period or according to the average heat energy indicator by month for the previous year. Tt is the tariff set for heat energy. Total - the volume of heat that is needed to heat the entire living space. ∑Tot is the volume of all heat energy consumed in residential and non-residential premises of a high-rise building.

To calculate the Obt indicator, you also need a formula:

Obt = Plz x (From / (Plob - Plind + Ploi))

Ploi - the area of ​​​​those premises that are for common use. Plind is the area of ​​residential and non-residential rooms in which there are no heating devices or their own heaters are installed.

The calculation is carried out according to the following formula:

∑Obt: From/ (Plob + Ploi) x Plob

If in one residential building an individual metering device (IMU) is installed in at least one of the apartments, it is included in the calculation of the total payment for heating. To calculate payments in houses where IPU is installed in several apartments, the same formula is used as for houses with ODPU, but without IPU.

For those premises in which there is no IPU, the Obt indicator is calculated as follows:

Obt = Plzh x (∑ObtIPU / ∑PlzhIPU)

∑ObtIPU - the total amount according to the indications of the IPU, if the calculation and accrual of payment occurs during the heating season. Or by the average monthly heat volume for the previous year. ∑PlzhIPU - area of ​​all rooms with IPU.

It’s not easy to count the first time, but even the second time, it becomes clear what indicator and what meter readings should be inserted where

What temperature should be maintained in apartments?

Heating standards in apartment buildings during the cold season:

Room typeOptimal temperature in degrees CelsiusPermissible temperature in degrees Celsius
Living room20-2218-24
Living room in regions with an outside temperature of -31°C or lower21-2320-24
Kitchen19-2118-26
Corridor between apartments18-2016-22
Toilet19-2118-26
Bathroom24-2618-26
Lobby, landing16-1814-20
Pantry16-1812-22

In the warm season, the norm for living rooms is optimally 22-25°C, and acceptable - 20-28°C.

If the temperature in your apartment during the heating season does not meet the established standards, you can contact the service company or utility service. They are required to investigate and obtain evidence. In this case, heating payments will be reduced. But such a solution can be called a half-measure, and it will suit few people, because the apartment will still remain uncomfortable living conditions.

Help from specialists

If at this moment it is suddenly unclear to you how to install heating in an apartment, then for this you need to contact qualified specialists. They will tell you everything and recommend how to choose the optimal parameters. First, a project is carried out, which shows an approximate layout of the heating system in the room.

After all the nuances have been clarified and approved, you can purchase equipment and ask about additional heating solutions in the house. The main thing is not to allow initiative in this matter, otherwise the system may break down and flood the neighbors, who are unlikely to be grateful to you for such a gift.

How to reduce payments

To reduce the amount of monthly payments for heat, the only way is to install individual heat meters. But before that, you may encounter several problems:

  1. Obtaining permission to install an IPU is a time-consuming process. In order for the installation to be approved, the technical specifications must be confirmed or improved. Based on them, the appropriate type of meter is selected.
  2. To regularly pay for heating using an individual meter, you need to send meters for verification in a timely manner. To carry it out, the meter is dismantled and reinstalled, which entails additional costs. If the verification takes place during the heating season, then payment for heating the apartment for a time without IPU is carried out according to the established standard. Therefore, it is better to return meters in the summer, although there may be long queues at this time.
  3. Expensive installation of IPU. Payment for the installation of one meter can reach 25 thousand rubles. Some companies charge a separate fee for dismantling. In addition, verification is also paid. And if the meter does not pass verification by the technical service or breaks down, it must be replaced in a timely manner.

Despite the complexity and large investment during initial installation, using a custom appliance can significantly reduce your monthly heating bills.

An example of calculating the thermal loads of a commercial facility

This room is on the first floor of a 4-story building. Location: Moscow.

Initial data on the object

Address of the objectMoscow
Number of floors of the building4 floors
The floor on which the premises being examined are locatedfirst
Area of ​​premises inspected112.9 sq.m.
Floor height3.0 m
Heating systemSingle-pipe
Temperature chart95-70 degrees. WITH
Estimated temperature chart for the floor on which the room is located75-70 degrees. WITH
Bottling typeUpper
Estimated indoor air temperature+ 20 degrees C
Heating radiators, type, quantityCast iron radiators M-140-AO – 6 pcs. Bimetallic radiator Global (Global) – 1 pc.
Heating system pipe diameterDN-25 mm
Heating system supply pipe lengthL = 28.0 m.
DHWabsent
Ventilationabsent
Heat load according to the contract (hour/year)0.02/47.67 Gcal

The calculated heat transfer of the installed heating radiators, taking into account all losses, was 0.007457 Gcal/hour.

The maximum heat energy consumption for heating the room was 0.001501 Gcal/hour.

The final maximum flow rate is 0.008958 Gcal/hour or 23 Gcal/year.

As a result, we calculate the annual savings for heating this room: 47.67-23 = 24.67 Gcal/year. This way you can cut your heating energy costs by almost half. And if we take into account that the current average cost of Gcal in Moscow is 1.7 thousand rubles, then the annual savings in monetary equivalent will be 42 thousand rubles.

The essence of the work of the IPU

An individual meter, which is connected to the heating system, takes into account heat energy consumption in the form of calculating the difference between the temperature achieved in the room and the coolant flow rate. Before installing IPU in your apartment, determine which heating system wiring in your high-rise building is vertical or horizontal.

The meters are attached directly to the heat supply pipe. If you have a vertical distribution system in a high-rise building, you will have to install one metering device for each pipe, and this is a very expensive undertaking. Each room will require a separate meter. There is no such problem with a horizontal system; only one device is enough. If the heating system is a riser system, distributors can be installed on the radiators. They calculate coolant flow by calculating the temperature difference in the room and from the surface of the radiator.

As a rule, high-rise buildings built after 2000 have a horizontal heating system. Therefore, it will be cheaper to install an IPU in a new building than in Soviet-built apartments. After installing the meter, the craftsmen seal it to prevent fraudulent activities on the part of residents or tenants.

Find out also how to save on electricity and pay utilities without commission.

5 / 5 ( 2 voices)

about the author

Klavdiya Treskova - higher education with qualification “Economist”, with specializations “Economics and Management” and “Computer Technologies” at PSU. She worked in a bank in positions from operator to acting. Head of the Department for servicing private and corporate clients. Every year she successfully passed certifications, education and training in banking services. Total work experience in the bank is more than 15 years. [email protected]

Is this article useful? Not really

Help us find out how much this article helped you. If something is missing or the information is not accurate, please report it below in the comments or write to us by email

Alternative options

Just as there are various ways to provide housing with heat by choosing a coolant - water or steam, there are also alternative methods for calculating the heat received. Here are two more formulas:

Thus, you can do the calculations yourself, but it is important to coordinate your actions with the calculations of the heat supply organizations. Their calculation instructions may be completely different from yours.

The calculations will be much more complicated if you plan to install heated floors in the house, but here you will need to turn on electricity. And this is a completely different “opera”, with new performers, but from the same government agencies

Helpful advice. Often reference books provide information not in the national system of units of measurement, to which calories belong, but in the international system “C”. Therefore, we advise you to remember the coefficient for converting kilocalories to kilowatts. It is equal to 850. In other words, 1 kilowatt is equal to 850 kilocalories. From here it is not difficult to convert gigacalories, given that 1 gigacalorie is a million calories.

The calculation is even more necessary when it comes to heating a country house.

All meters, and not only the simplest brownie meters, unfortunately suffer from some measurement error. This is a normal situation, unless, of course, the error exceeds all conceivable limits. To calculate the error (relative, in percent), a special formula is also used:

  • V1 and V2 are the previously discussed coolant flow rates, and
  • 100 – conversion factor to percentage.

The percentage of error when calculating heat is considered acceptable - no more than 2 percent, given that the error of measuring instruments is no more than 1 percent. You can, of course, make do with the old proven method; here you don’t need to do any special calculations.

This solution is sometimes life-saving and the most convenient.

Comments: 5

Your comment (question) If you have questions about this article, you can tell us. Our team consists of only experienced experts and specialists with specialized education. We will try to help you in this topic:

Author of the article: Klavdiya Treskova

Consultant, author Popovich Anna

Financial author Olga Pikhotskaya

  1. Ray
    01/22/2022 at 22:45 In an apartment building, an OPU PO 261-FZ was installed, last summer the device was taken out of service (the reasons are not given, the device is broken), but we are still paying in installments for the installation and maintenance of a non-working device.
    Question: -Should we pay for this non-working device? -How should you pay for heating in this case? Reply ↓
  2. Yuri
    12/22/2021 at 12:45

    Hello dear experts. Please answer, does the heating supplier have the right to charge payment according to the standard 2 weeks before the start and 2 weeks after the end of the 8-month heating season if a common building heat meter is installed? It turns out that we pay for 8 months according to the meter and the ninth month according to the standard, with the exception of 3 months of summer. Thank you for your answer.

    Reply ↓

  3. Irina
    11/22/2021 at 10:08 am

    If an apartment building receives coolant from the boiler room, but an additional boiler is installed in the house, how does this affect the amount of payment for heat? Is it possible to somehow control the accuracy of the calculations?

    Reply ↓
    Anna Popovich
    11/25/2021 at 7:18 pm

    Dear Irina, when preparing hot water using the in-house engineering systems of an apartment building (in the absence of a centralized preparation of hot water), the amount of payment for hot water supply is calculated based on meter readings and the corresponding tariffs for cold water and fuel used to prepare hot water. At the same time, the costs of maintaining and repairing in-house engineering systems used for preparing hot water are included in the fee for maintaining and repairing residential premises.

    Reply ↓

  • Andrey
    09.13.2021 at 12:59

    The house has a common heating supply meter. There is no countdown counter! how the heat consumption should be calculated.

    Reply ↓

  • Example 3

    For a steam heating system, it is necessary to determine the number and length of cast iron finned pipes, provided that the installation is open and made in two tiers. In this case, the excess steam pressure is 0.02 MPa.

    Additional characteristics: tаc= 104.25 °С, tв=15 °С, Qп = 6500 W, Qtr = 350 W.

    Using the formula µ tн = tsat - tв, we determine the temperature difference:

    µ tn = 104.25-15 = 89.25 °C.

    We determine the heat flux density using the known transmission coefficient of this type of pipe in the case when they are installed in parallel one above the other - k = 5.8 W/(m2-°C). We get:

    qnp = knpх µ tн = 5.8-89.25 = 518 W/m2.

    The formula Ap = Qnp/qnp helps determine the required area of ​​the device:

    Ar = (6500 - 0.9x350) / 518 = 11.9 m2.

    To determine the number of pipes needed, N = Ap / (nxa1). In this case, you should use the following data: the length of one tube is 1.5 m, the heating surface area is 3 m2.

    We calculate: N= 11.9/(2x3.0) = 2 pcs.

    That is, in each tier it is necessary to install two pipes, each 1.5 m long. In this case, we calculate the total area of ​​this heating device: A = 3.0x*2x2 = 12.0 m2.

    https://youtube.com/watch?v=mVNWfHKN-Pw

    Rating
    ( 2 ratings, average 5 out of 5 )
    Did you like the article? Share with friends:
    For any suggestions regarding the site: [email protected]
    Для любых предложений по сайту: [email protected]