Combined gas-wood boilers are, first of all, solid fuel boilers that have only a slightly modified design into which you can install a gas burner that burns natural or liquefied gas. Replacing the burner is done quite quickly, on your own, according to the manufacturer’s instructions, so combination boilers are multifunctional and, despite different opinions, retain the reliability and durability of simple solid fuel and gas models.

Despite all the advantages, we do not recommend considering combined models (with the exception of a few cases), since purchasing a separate gas boiler and a solid fuel boiler will cost much less, and the disadvantages of a dual-fuel design are often significant. Let's look at everything in order.

What are gas-wood combination boilers?

Mixed-type boilers operating on solid fuel and gas are always a floor-standing design, the dimensions corresponding to conventional solid fuel models. Without the use of a gas burner, these are ordinary solid fuel boilers that burn not only wood, but also coal, pellets, peat, and anthracite. Piping, installation and connection of universal boilers is carried out similarly to single-fuel boilers.

Why are they needed and how are they used?

As we have already said, without special conditions, the purchase of a gas-solid fuel boiler is not justified either economically or practically.

Firstly , the total cost of separately purchased gas and solid fuel boilers is 90% lower than the combined model. The cost of gas-wood boilers is 19,000-35,000 rubles and the gas burner is not included in this amount: it must be purchased separately. Only in rare cases are ready-made assemblies found with a gas burner included. The cost of the burner is on average another 6-12 thousand rubles.

The most economical of the budget simple boilers for heating a private home

Secondly , the efficiency and functionality of individual single-fuel models is almost always higher than combined ones. The usual design of a solid fuel boiler does not show the highest efficiency (at best, up to 85%) when burning natural or liquefied (cylinder) gas, when even budget gas boilers have an efficiency of 88-92%. And this, accordingly, is lower consumption with the same heat transfer. Also, combined gas-wood boilers are devoid of any functional automation, which is found even on budget gas models.

Thirdly , a small bonus of two single-fuel boilers is that if one breaks down, the second can be used as a backup.

However, there are cases when buying a universal boiler that runs on gas and wood may be more profitable. For example:

  • if you have access to any type of solid fuel for a symbolic price. When solid fuel reserves are exhausted, stable combustion without human intervention is required, or a previously missing gas line is installed near the house, you can always switch to a gas burner;
  • if the area of ​​the house is quite small and allocate at least 8 square meters. m. area for separate single-fuel boilers is impossible.

Design and principle of operation


Combined model with an installed gas burner.
Diagram using the Teplodar Kupper OK 15 model as an example. The design of such boilers is traditional: solid fuel is burned in the combustion chamber, the walls of the chamber are a heat exchanger, inside of which the coolant circulates through the system. Fuel is loaded through the door at the front, and ash is collected in the ash drawer below.

If you need to switch to gas, a gas burner with the appropriate fastening (without welding) is installed on the ash pan door or a specially designated mount. However, the design of the heat exchanger, designed for a large combustion chamber volume, accumulates much less thermal energy when burning gas; the efficiency remains only within 75-85%, as when burning high-quality solid fuel.

There are also high-tech hybrid models on the market with 2 fireboxes, in which fuel can be burned simultaneously. Solid fuel is usually burned in the upper combustion chamber, a gas burner is installed in the lower one, and a compact ash box and heat exchanger design separate the combustion chambers. However, the cost of such models is in the range of 200-350 thousand rubles.


Two-furnace model.

Boilers with a burning duration of one load of fuel up to 7 days

Are there any special features in operation?

When purchasing a combined boiler with wood and gas heating, you need to take into account several operational points, without which the use of firewood as the main source of heat can lead to the fact that the universal method will cause considerable problems.

So, during its operation, a wood-burning boiler gradually clogs the chimney with soot, which must be periodically cleaned. Without this, the efficiency of smoke removal will gradually decrease, until problems with ignition, smoke in the room, etc. appear.


Rice. 4 Chimneys require regular cleaning

If gas or electric heating can operate continuously, then a wood-burning boiler burns out completely after a maximum of 3-4 hours, after which the heating system inevitably begins to cool down. Loading a new portion is done manually, which requires the owner's home. Therefore, combined modifications with wood or pellet fuel are often used, if possible, in gas heating mode.

Pellets partially allow you to automate the heating procedure with wood fuel, but you still have to monitor the process. And the reserve must be created in advance, otherwise you may be left without heating during the coldest period of the year.

Reviews of universal solid fuel and gas boilers: advantages and disadvantages

AdvantagesFlaws
Significant space savings, which is especially important for small houses with an area of ​​40-80 m2. The dimensions of combined models do not differ from single-fuel models Primitive automation or its complete absence (mechanical traction control)
Availability of single-circuit and double-circuit modelsIn more than 95% of cases, a gas burner is not sold complete with the boiler
Almost all models are non-volatile (do not require connection to the mains)Owners often note the rather high noise level of the burners, which is not comparable to the standard burners of gas boilers.
In combined models, durable cast iron heat exchangers are often used, while budget solid fuel and gas heat exchangers almost always use steel ones that are vulnerable to corrosion.Higher requirements for chimney draft, which complicates calculations. If the design is incorrect, the thrust may not be sufficient for complete combustion of gas.
Small selection of multi-fuel combined models, especially foreign ones

How to choose a combi boiler

The selection criteria are almost the same as when choosing a TT model. You definitely need to decide on:

  1. Number of contours . Single-circuit models are more common; they heat only the heating circuit. Double-circuit models are also capable of heating sanitary water (it does not mix with process water from the heating circuit). Double-circuit models are 10-40% more expensive, but this is still the cheapest way to organize hot water supply in a house.
  2. Burnt fuel . Basically, combined boilers are designed to burn both coal and charcoal, firewood, pellets, and peat. Models with a cast iron heat exchanger are capable of burning anthracite. But some boilers are designed only for firewood. Types of fuel are always described in the technical specifications or boiler passport.
  3. Heat exchanger material . There are two options: steel or cast iron. Steel heat exchangers are inexpensive to produce, lightweight, resistant to temperature changes and mechanical damage, but have thin walls and are not resistant to corrosion; their service life is on average 12-15 years. Cast iron heat exchangers are heavy, have thick walls, are not subject to corrosion and last more than 30 years, but are used in more expensive models.
  4. Working pressure . Some models are designed for an operating pressure in the system of no higher than 1 bar, which means that they cannot be used in closed heating systems with forced circulation, where the operating pressure is usually 1.5-2 bar.
  5. Efficiency . It is not the most informative indicator when burning solid fuel, since it strongly depends on its quality (dryness and type of wood, ash content and calorific value of coal). However, when using a gas burner, 4-5% efficiency can pay for the higher cost in one heating season. The optimal efficiency indicator is 80% and above.

Minimum required power

For an average uninsulated or poorly insulated house in the climatic zone of the Moscow region, with 2 bricks and a ceiling height of 2.7 m, the minimum required power is calculated using a simple formula: 1 kW for every 10 m2. We also recommend setting aside a power reserve of 20-30%.

For example, for the average house described above with an area of ​​100 m2, the minimum required power of heating equipment is 100/10 * 1.3 (30% reserve) = 13 kW. Boilers of this power are not found on the market, so we round up to the nearest higher value - 14 or 15 kW.

Also, when purchasing a double-circuit boiler, it is recommended to add another 10-15% to the result, since when heating hot water, the heating circuit is not heated. Total 13 kW * 1.1 (10% reserve) = 14.3 kW. If the house is located in the extreme southern or northern point of the country, is well insulated, has high ceilings or a large glazing area, correction factors are taken into account, changing the result by 5-30% up or down.

How to accurately calculate the required boiler power Individual calculation, formula and correction factors

Equipment installation

Installation of a gas boiler is carried out in frost-free rooms . The installation location must be agreed upon with specialized services.

Before choosing a location for installation, it is necessary to plan how combustion products will be removed. This is usually done by installing separate pipes , or using existing chimneys. The chimney system is often included.

First, the floor is prepared. Since the boiler is heavy, the base underneath must be strong. If necessary, the screed is poured. The floor under the boiler must have a fireproof coating . In its absence, hollow concrete blocks are placed on the floor and covered with a sheet of metal on top. The height of the blocks is 100 mm, the thickness of the metal is 0.8 mm. It is also possible to use fireproof boards.

If the surface is covered with non-flammable materials, then there should be
at least 10 cm from the device to the wall. To place the device close to each other, the wall must be finished with fire-resistant materials. The base of the wall is insulated with roofing steel laid on asbestos with a thickness of 30 cm. The dimensions of the device body around the perimeter are at least 10 cm. All protruding parts of the boiler, parts of the fittings are removed from the walls by at least 1 m.
The boiler must be installed as level as possible. Checking is carried out using a building level. If necessary, place a solid non-combustible material under the legs of the device. The equipment is connected to the in-house heating system and to the chimney. A double-circuit boiler is connected to a cold water pipeline.

It is advisable to install the boiler so that it is easy to dismantle . Shut-off valves are installed on all pipes of the device. They are needed to dismantle equipment without discharging water from the existing system.

Work on installing the boiler can be carried out independently, however, for safety reasons, it is better to carry out the first start-up of the equipment with a specialist.

The best known manufacturers and models: characteristics and prices

Teplodar Kupper OK 15

The most famous domestic combination boiler, burning coal, wood, pellets, natural gas (when installing a burner). It is distinguished by time-tested reliability at a low cost, successful design of the firebox, and ease of cleaning. Separately, it is worth noting the presence of blocks of heating elements with a power of 6 kW, with the help of which you can heat the coolant for a long time if the solid fuel burns out completely at night. The owners also note a rather nice stylish design and build quality.

However, there are also a sufficient number of disadvantages: a small loading hole and the firebox itself (firewood up to 35 cm), a steel heat exchanger, relatively low efficiency, high soot formation.

Viadrus Hercules U22 D-4

One of the best combined gas-wood boilers for heating a private home, also one of the most popular. The Czech model with a cast iron heat exchanger is characterized by ease of use and well-known durability, ensured by good alloys and build quality. The boiler has a fairly good efficiency of 80%, is absolutely omnivorous, has an optimal firebox size (firewood 40-45 cm long can be placed), and also has compact dimensions and a stylish appearance.

According to reviews from owners, when the draft valve is tightly closed, abundant soot formation is typical. The cast iron structure, depending on the power variation, weighs on average 250 kg, so a reinforced floor is required for installation, and at least 3 people for transportation. Also a relative disadvantage is the price of the Czech model.

Roda Brenner Classic BCR-04

Another practically standard Czech combi boiler with a cast iron heat exchanger and a technologically advanced, efficient and practical design. The body is separated by a layer of thermal insulation, which reduces heat loss through the boiler modules and keeps the body relatively cold. Everything is also distinguished by Czech reliability, practicality during operation and cleaning, and good efficiency.

According to installation experience and reviews from owners, no shortcomings or malfunctions were found over more than 6 years of operation. One can only note that the price is still high for the average Russian buyer.

Cost: 53,000-55,000 rubles.

HEPHAESTUS VPR KSTGV-20

Inexpensive and compact double-circuit combi boiler of domestic production. It has a good efficiency of 80%, achieved thanks to the excellent design of the heat exchanger. The primary heat exchanger is steel, but the secondary (for DHW) is made of copper. Almost always, the factory equipment includes a gas burner of the “BRAY” type with the well-known simple Italian SIT automatic system.

Please note that the maximum permissible operating pressure is only 1 bar. It is also worth noting that the model is quite rare on sale.

Cost: 23,500-26,400 rubles.

Karakan 20 TEGV

Another domestic dual-circuit model. It has the simplest possible design, is not demanding on fuel, has a large loading opening and firebox, as well as a block of heating elements installed from the factory.

However, the heat exchanger is made of steel, the efficiency is only 75%, the weight is 101 kg, and the maximum permissible operating pressure is 1 bar. There have been no service complaints over more than 5 years of operation.

Using long-burning TT boilers

Not every homeowner has the technical ability to connect powerful electrical equipment, which includes combined and purely electric boilers. The reason is the limitation of the allocated power limit for a private house. The size of the limit depends on the capacity of local power supply networks, which the owner of a country cottage cannot increase.

In the absence of natural gas on the site or with the high cost of connecting to the main line, there is only one real solution - buy a long-burning wood and coal boiler or make it yourself. The operating time from 1 load for a conventional TT boiler is 3-6 hours, which forces the owner to work near it as a stoker. A comfortable interval between fuel additions is at least 8 hours, and not every heater provides that much.


The latest pyrolysis boiler with an increased firebox volume ATMOS D30

The trouble is that any seedy manufacturer calls their products long-burning boilers in order to sell them to an ignorant user. You can recognize the correct unit among other heat generators by the following features:

  • with the same power, a boiler with a large power reserve is equipped with a firebox of increased volume (from 100 l) and differs in size;
  • the passport indicates a burning duration of 8 hours (on wood);
  • For convenience, the unit is equipped with an additional loading door.

Detailed information about heat generators of this type and recommendations for their selection are published in a separate topic.

Prices: summary table

Manufacturer and modelHeat exchanger materialNumber of circuitsEfficiency, %price, rub.
Teplodar Kupper OK 15steelsingle-circuit7826 900-36 200
Viadrus Hercules U22 D-4cast ironsingle-circuit8083 000-90 500
Roda Brenner Classic BCR-04cast ironsingle-circuit8053 000-55 000
HEPHAESTUS VPR KSTGV-20steeldouble-circuit8023 500-26 400
Karakan 20 TEGVsteeldouble-circuit7528 500-31 000

How to select a gas burner for a solid fuel boiler


Model AGG-13K
Universal gas burners for solid fuel boilers, which are not included in the factory components of specific models, are suitable for all boilers, since they have a fairly simple screw fastening. The exception is burners designed for a specific model range. Usually these are burners from the same manufacturer as the boiler. Their name or characteristics indicate, for example, “...for Teplodar boilers.”